Programs for the Evaluation of 3D PET Reconstruction Algorithms
1
25
Medical Image Processing Group,
19
Department of Radiology,
20
University of Pennsylvania
1
45
EVAL3DPET is a set of programs designed to statistically evaluate 3D
46
PET reconstruction algorithms. The software comprises of tools for 3D
43
phantom and projection data generation, evaluation and statistical
45
comparison, and it includes some fully 3D reconstruction algorithms.
4
1
3f
The EVAL3DPET programming system is designed to be capable of:
5
48
- Generating phantom and projection data based on a realistic 3D PET
44
scanner model. The phantoms are random samples from a statistically
42
described ensemble of 3D images with 69 ellipsoid features (cold,
40
normal and hot) ranging from small (4 mm) to large (40 mm). The
45
projection data generation takes into account detector field-of-view
2f
blurring and a realistic 3D PET noise model.
1
14
- Evaluating for
3a
structural accuracy, hot spot detectability and cold spot
10
detectability.
1
37
- The evaluation program also calculates a training
40
figure-of-merit, that can be used for optimizing reconstruction
3f
techniques. Statistically comparing the efficacy of a pair of
2c
reconstruction techniques using the t-test.
9
1
45
Included, as examples, are the ART and EM reconstruction techniques,
47
both implemented using traditional voxels and also using the so-called
41
"blob" basis functions. Our implementations of ART use a special
47
data-access ordering (of projection rays) to achieve fast convergence.
3d
The EM algorithms support both attenuated and non-attenuated
11
projection data.
4
1
25a
EVAL3DPET will be made available (on a CD ROM) to all who request it at the cost of reproduction and mailing of the C source code, manual and example data files. The programs were developed using the C language (K&R), under a UNIX operating system, and they have been tested on SPARCstations (SUN) and Silicon Graphics machines. There is a charge of US$150.00 (checks only) for providing this service. (For overseas mailing add another US$50.00 if air mail delivery is required.) Please make the check payable (in US currency drawn on a US bank) to RADIOLOGY ASSOCIATES and send it with your order to:
1
d
a
12
Ms. Mary Blue
23
Medical Image Processing Group
2f
Dept. of Radiology - Univ. of Pennsylvania
1d
Blockley Hall, 4th Floor
16
418 Service Drive
20
Philadelphia, PA 19104-6021
a
U.S.A.
19
Tel: +1-215-662-6780
19
Fax: +1-215-349-8426
1b
email: mary@mipg.upenn.edu
b
e
1
47
By purchasing the EVAL3DPET software, the recipient agrees to abide by
15
the following terms:
5
36
- EVAL3DPET shall not be redistributed in any way.
1
4a
- EVAL3DPET is not a patient-care tool and it is not approved by the
30
United States Federal Drug Administration.
1
4e
- While every effort has been made to correct all known bugs, EVAL3DPET is
45
provided "as is" with no warranty whatsoever. As such, the recipient
45
agrees not to hold the authors responsible for any problems they may
1f
encounter with the software.
1
4c
- The recipient agrees to purchase EVAL3DPET with the explicit knowledge
31
that the authors do not offer technical support.
6
1
1a
8a
Medical Image Processing Group, Department of Radiology, University of Pennsylvania Health System
1
1a
42
1
8
8
0